Call: +44 (0)1622 872401
Address: Unit 1 Branbridges Industrial Estate, East Peckham, Kent
  • High quality Process Control Instrumentation
  • All our products are made in UK to our design or to match your own customer’s specifications.
  • We offer fast turnaround time, competitive pricing, and no minimum order quantity.
  • Bespoke artwork and laser engraving of logos or QR codes are also available.
  • MPB offers fast turnaround, competitive pricing, no minimum order quantity.
  • All our products are made in UK to our design, or to match your own specifications.
  • Bespoke artwork and laser engraving of logos, or QR codes are available.

Series TX200 Transmitting Variable Area Flowmeter

GENERAL INFORMATION

The MPB Series TX200 Metal Tube VA Flowmeter has been designed to measure flow volumes of aggressive chemicals at higher-than-average pressures.
As standard supplied with 1/8” NPT female end connections.

 

Download Technical Bulletin which shows standard flow rates: Technical Bulletin

Download Installation Instructions: Installation Instructions

For further information please complete the form below, or contact us direct by telephone or e-mail.

Tel: +44 (0)1622 872401
Email: sales@mpbflowmeters.com

 

Description

SERIES TX200 METAL TUBE VARIABLE AREA FLOWMETER FEATURES

• FLOW METERING OF GASES AT PRESSURES UP TO 700 PSI AND TEMPERATURES TO 150°C
• PRECISE FLOWRATE CONTROL VIA AN INLET CONTROL VALVE
• 316 (A4) STAINLESS STEEL FLOW PARTS GIVES EXCELLENT CORROSION RESISTANCE
• ROBUST DESIGN
• VERTICAL CONNECTIONS
• NON-VALVED VERSION AVAILABLE
• COMPACT DESIGN
• VITON VALVE SEAL
• OPTIONAL ADJUSTABLE 4- 20 mA OUTPUT
• OPTIONAL ADJUSTABLE HIGH & LOW FLOW ALARM CONTACT OUTPUTS CONFIGURABLE AS NO OR NC

Enclosure: Aluminium
Standard Scale: 0-100% (Optional 10:1 calibrated)
Standard Seals: Viton
Metering Tube: 316 Stainless Steel
Float: 316 Stainless Steel
Weight: 1kg
Accuracy: +/- 5% FSD predicted
Maximum Working Pressure: up to 50 bar g
Maximum Working Temperature: 150°C (Viton)

Electrical Specifications:
4-20mA Features:
• Wide 6-36Vdc input voltage supply range
• 0.05mA output resolution
• Easy push button setup
• Optional NAMUR NE43 extended working range and diagnostics mode

Alarm Option:
• Separate 7.5-12Vdc input voltage supply required
• Individual upper and lower alarm relays and output connections
• Relay contact ratings: 48Vdc/0.1A ( 5 W max )
• Easy push button alarm level setting
• Relays configurable as NO or NC

Reviews

There are no reviews yet.

Be the first to review “Series TX200 Transmitting Variable Area Flowmeter”

Your email address will not be published. Required fields are marked *