<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Veterinary Gas Anaesthesia Variable Area Flowmeters &#8211; MPB Industries</title>
	<atom:link href="https://www.mpbflowmeters.com/product-category/medical-veterinary/veterinary-gas-anaesthesia-variable-area-flowmeters/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.mpbflowmeters.com</link>
	<description></description>
	<lastBuildDate>Tue, 04 Nov 2025 12:38:42 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>
	<item>
		<title>Series 1600 Single and Dual Tube Veterinary Gas Variable Area Flowmeters</title>
		<link>https://www.mpbflowmeters.com/product/series-1600-single-and-dual-veterinary-gas-variable-area-flowmeters/</link>
		
		<dc:creator><![CDATA[Jamie Burchell]]></dc:creator>
		<pubDate>Wed, 03 Sep 2025 12:15:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.mpbflowmeters.com/?post_type=product&#038;p=52</guid>

					<description><![CDATA[MPB produces a comprehensive range of veterinary anaesthetic flowmeters complete with safety cover, independent control valves, illuminous backing and earthing tags, suitable for trolley or wall mounting.]]></description>
										<content:encoded><![CDATA[<h3>Features (Single and Dual Tube)</h3>
<ul>
<li>All MPB flowmeters for anaesthetic gases conform to ISO 5358 / BS 4272 being electrically conductive</li>
<li>MPB can also supply complete tube and float assemblies independently</li>
<li>Accuracy of measurement is to class 2.5 VDI/VDE 3513 or better</li>
<li>Process connections: Alochromed Aluminium, ¼” BSPPF, or ISO 23mm taper outlet. <em>(Please state when ordering)</em></li>
<li>Our MPB design team will be pleased to discuss existing or new products, i.e. customised designs, scales, tube lengths, etc</li>
<li>Colour banding supplied as standard</li>
</ul>
<h3>Standard Flow Rates</h3>
<ul>
<li>0.1-1 L/min Air, 0.1-2 L/min Air, 0.1-4 L/min Air, 0.1-8 L/min Air, 0.1-10 L/min Air, 0.1-15 L/min Air</li>
<li>0.1-1 L/min 02, 0.1-2 L/min 02, 0.1-4 L/min 02, 0.1-8 L/min 02, 0.1-10 L/min 02, 0.1-15 L/min 02</li>
<li>0.1-1 L/min N20, 0.1-2 L/min N20, 0.1-4 L/min N20, 0.1-10 L/min N2O, 0.2-12 L/min N20</li>
</ul>
<ul>
<li>Please note that we have a wide range of flow rates to suit these instruments.  Please contact MPB sales office for full details</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Series 1650 Special Veterinary Gas Variable Area Flowmeter</title>
		<link>https://www.mpbflowmeters.com/product/series-1650-special-veterinary-gas-variable-area-flowmeter/</link>
		
		<dc:creator><![CDATA[Jamie Burchell]]></dc:creator>
		<pubDate>Wed, 03 Sep 2025 12:16:12 +0000</pubDate>
				<guid isPermaLink="false">https://www.mpbflowmeters.com/?post_type=product&#038;p=79</guid>

					<description><![CDATA[The MPB Series 1650 Veterinary Gas Flowmeter consists of a polycarbonate safety cover, integral flow control valve and is suitable for trolley, or wall mounting.]]></description>
										<content:encoded><![CDATA[<h3>Features</h3>
<ul>
<li>Easy in-situ tube removal</li>
<li>The flowmeter has a photo luminescent backing to provide a degree of back lighting in the event of a power failure</li>
<li>Accuracy of measurement is +/- 2% FSD, or better</li>
<li>Process connection: 1/8&#8243; NPTF, black anodised aluminium</li>
<li>Flow tube is supplied complete with colour banding to international standards</li>
<li>Removable flow control cartridge design to allow quick and easy servicing</li>
<li>Can be supplied with a ball float, or a red anodised &#8216;fast recovery&#8217; fluted plumb bob float</li>
<li>Safety collar to prevent shut off</li>
</ul>
<h3>Standard Oxygen Flow Rates</h3>
<ul>
<li>0.05-1 L/min O2 @ 1013 mbar abs 20<sup>o</sup>C</li>
<li>0.05-2 L/min O2 @ 1013 mbar abs 20<sup>o</sup>C</li>
<li>0.1-4 L/min O2 @ 1013 mbar abs 20<sup>o</sup>C</li>
<li>0.1-8 L/min O2 @ 1013 mbar abs 20<sup>o</sup>C</li>
<li>0.1-10 L/min O2 @ 1013 mbar abs 20<sup>o</sup>C</li>
<li>0.1 &#8211; 4 L/min N2O @ 1013 mbar abs 20oC</li>
<li>0.1 &#8211; 10 L/min N2O @ 1013 mbar abs 20oC</li>
<li>0.1 &#8211; 4 L/min Air @ 1013 mbar abs 20oC</li>
<li>0.1 &#8211; 10 L/min Air @ 1013 mbar abs 20oC</li>
<li>Other gases available upon request</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Series 1600 Triple Tube Veterinary Gas Variable Area Flowmeter</title>
		<link>https://www.mpbflowmeters.com/product/series-1600-triple-tube-veterinary-gas-variable-area-flowmeter/</link>
		
		<dc:creator><![CDATA[Jamie Burchell]]></dc:creator>
		<pubDate>Wed, 03 Sep 2025 12:16:33 +0000</pubDate>
				<guid isPermaLink="false">https://www.mpbflowmeters.com/?post_type=product&#038;p=113</guid>

					<description><![CDATA[MPB produces a comprehensive range of veterinary anaesthetic flowmeters complete with safety cover, independent control valves, illuminous backing and earthing tags, suitable for trolley or wall mounting.]]></description>
										<content:encoded><![CDATA[<h3>Features</h3>
<ul>
<li>All MPB flowmeters for anaesthetic gases conform to ISO 5358 / BS 4272 being electrically conductive</li>
<li>MPB can also supply complete tube and float assemblies independently</li>
<li>Accuracy of measurement is to class 2.5 VDI/VDE 3513 or better</li>
<li>Process connections: Alochromed Aluminium, ¼” BSPPF, or ISO  23mm taper outlet</li>
<li>Our MPB design team will be pleased to discuss existing or new products, i.e. customised designs, scales, tube lengths, etc</li>
<li>Colour banding supplied as standard</li>
</ul>
<h3>Standard Flow Rates</h3>
<ul>
<li>0.1-1 L/min Air, 0.1-2 L/min Air, 0.1-4 L/min Air, 0.1-8 L/min Air, 0.1-10 L/min Air, 0.1-15 L/min Air</li>
<li>0.1-1 L/min 02, 0.1-2 L/min 02, 0.1-4 L/min 02, 0.1-8 L/min 02, 0.1-10 L/min 02, 0.1-15 L/min 02</li>
<li>0.1-1 L/min N20, 0.1-2 L/min N20, 0.1-4 L/min N20, 0.1-10 L/min N2O, 0.2-12 L/min N20</li>
<li>Please note that we have a wide range of flow rates to suit these instruments.  Please contact us for full details</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Series 1200BV-ANS/230 Anaesthetic Variable Area Flowmeter</title>
		<link>https://www.mpbflowmeters.com/product/mpb-series-1200bv-ans-230-anaesthetic-variable-area-flowmeter/</link>
		
		<dc:creator><![CDATA[Jamie Burchell]]></dc:creator>
		<pubDate>Wed, 03 Sep 2025 12:15:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.mpbflowmeters.com/?post_type=product&#038;p=53</guid>

					<description><![CDATA[This version of the MPB Series 1200BV-ANS/230 Flowmeter is manufactured exclusively to house an anaesthetic 230mm standard length flow tube and will give an instantaneous flow rate of the standard anaesthetic gases.

The MPB Series 1200BV-ANS/230 Anaesthetic Flowmeter has an overall length of 300mm, with process centres of 275mm.  This flowmeter is also available as a 1200BV-ANS/138 which has an overall length of 210mm and process centres of 185mm.

Normally the flow tube supplied exhibits dual scale calibration whereby the first third of the flow range is dedicated to 0.1-1 L/min and, for example, 2-10 L/min would be a linear scale for the remainder of the scale length.

The flow tube is fully conductive, both internally and externally, and is compliant to the international standard for human and veterinary anaesthesia flow measurement.

The flow tube utilises serial numbered floats and flow tubes to guard against incorrect reassembly when cleaning. In addition, the float exhibits a white dot so that the operator can clearly see the rotation.]]></description>
										<content:encoded><![CDATA[<h3>Features</h3>
<ul>
<li>Valved, or non-valved versions</li>
<li>Frictionless, hence low head loss</li>
<li>Easy in-situ tube removal and re-installation</li>
<li>Standard and customised flow scales available</li>
<li>Colour banding to international standard (please specify when ordering)</li>
<li>Has a photo luminescent backing to provide a degree of back lighting in the event of power failure</li>
<li>The flow tube is supplied complete with colour banding to international standards. Colour banding can also be supplied to other requirements</li>
<li>The flowmeter is fitted with a contact device to earth the flow tube through to the mounting studs and chassis. This is to prevent any static build up</li>
<li>In addition to standard anaesthetic gases, MPB can supply calibrated flow tubes for xenon, heliox, entinox, nitrox and nitric oxide as typical examples</li>
</ul>
<h3>Specification</h3>
<ul>
<li>Chassis: Anodised aluminium to BSEN12373</li>
<li>End Blocks: Nickel plated brass, or Stainless steel</li>
<li>Process Connections: G¼” rear facing, or straight through</li>
<li>Valve Stem: Stainless steel</li>
<li>Cover: Polycarbonate</li>
<li>Seals: Viton</li>
<li>Metering Tube: Borosilicate glass 230mm long with permanently fired scale and fully conductive to ISO 5358 and BS 4272</li>
<li>Scale: Permanently fired (black)</li>
<li>Weight: 670 grams</li>
<li>Plumb Bob Float: Red hard anodised aluminium with white rotation indicator</li>
<li>Maximum Working Pressure: Gas: up to 20 bar g (non-shock)</li>
<li>All flow tubes calibrated at 1013 mbar abs 20°C</li>
<li>Maximum Working Temperature: 100°C Viton</li>
<li>Accuracy: All flow tubes supplied with this instrument have been calibrated to confirm their accuracy falls within the limits set by ISO 5358 and Class 2.5 VDI/VDE 3513. All calibration equipment is traceable to National UK Standards</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>

<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Object Caching 60/195 objects using Memcached
Page Caching using Disk: Enhanced 

Served from: www.mpbflowmeters.com @ 2026-06-22 02:14:36 by W3 Total Cache
-->